2013年7月16日星期二

Feeder maintenance and operation instructions

 
1 feeder need to check in the course of the following
(1) Check the shaker feeder and amplitude, the amplitude must not exceed the feeder design limits.
(2) Check the main vibration rubber spring for cracks.
(3) Check the isolator springs for cracks.
(4) Check the fastening bolts are loose.
(5) Check the motor operation is abnormal sound.
2 feeder early running within a week, must be checked daily and tighten the connecting bolt, a week later, you can check and tighten every other day once, until the device is

running stable.
3 motor repair and maintenance instructions for use by the motor.
4 Practice Feeder
(1) Installation and vibrating feeder motor wiring, to conduct a comprehensive safety inspection, in order to avoid power accident occurred after the personnel and equipment to  Pipe conveyor

confirm the entire bolt, reliable grounding device before boot.
(2) feeder load running time should not be too long, less than 30 minutes after the shutdown, to all the bolts once, later to be regularly checked and found loose fastening

timely, vibration motors and equipment to ensure a firm connection.
(3) When the adjustment to the quantity, can be carried out by the following method.
a. adjustment to increase the vibration motor excitation force.
b. hanging length adjusting tank, the tank along the feed direction tilted down, the tilt angle is usually the case within the range from 0 to -140, according to the natural

angle of repose of the material to the principle of material does not automatically run.  industrial conveyor

没有评论:

发表评论